3-Phase Flexible Current Probe with 3VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths.
Electrical Characteristics
Current Ranges | 60A / 600A / 6000A AC RMS (selectable via rotary switch) |
Output Sensitivity | 50mV / 5mV / 0.5mV per A (AC coupled) |
Accuracy (at 25°C) | ± 1% of reading ± 0.1A (60A range) ± 1% of reading ± 1A (600A / 6000A range) |
Physical Characteristics
Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter | 9.9mm (nominal) |
Cable Length | 2m (Probe to Integrator box) |
Output | 0.5m long lead terminated with 3 X safety male BNC |
3-Phase Flexible Current Probe with 3VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges | 30A / 300A / 3000A AC RMS (selectable via rotary switch) |
Output Sensitivity | 100mV / 10mV / 1mV per A (AC coupled) |
Accuracy (at 25°C) | ± 1% of reading ± 0.1A (30A range) ± 1% of reading ± 1A (300A / 3000A range) |
Physical Characteristics
Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter | 9.9mm (nominal) Cable Length 2m (Probe to Integrator box) |
Output | 0.5m long lead terminated with 3 X safety male BNC |
1-Phase Flexible Current Probe [Compatible with Fluke 1750 and RPM Power Recorders] available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges | 100A / 1000A / 5000A AC RMS (selectable via rotary switch) |
Output Sensitivity | 20mV / 2mV / 0.4mV per A (AC coupled) |
Accuracy | (at 25°C) ± 1% of reading ± 0.1A (100A range) ± 1% of reading ± 1A (100A / 5000A range) |
Physical Characteristics
Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter | 9.9mm (nominal) |
Cable Length | 2m (Probe to Integrator box) |
Output | 0.5m long lead terminated with a 6-pin male LEMO |
Single Phase Flexible AC Current Probe with 3 VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges | 60A / 600A / 6000A AC RMS (selectable via rotary switch) |
Output Sensitivity | 50mV / 5mV / 0.5mV per A (AC coupled) |
Accuracy | (at 25°C) ± 1% of reading ± 0.1A (60A range) ± 1% of reading ± 1A (600A / 6000A range) |
Physical Characteristics
Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter | 9.9mm (nominal) Cable Length 2m (Probe to Integrator box) |
Output | 0.5m long lead terminated with a safety male BNC |
Single Phase Flexible AC Current Probe with 3 VDC Full-Scale Output available in 24, 36 and 48 inch probe cable lengths
Electrical Characteristics
Current Ranges | 30A / 300A / 3000A AC RMS (selectable via rotary switch) |
Output Sensitivity | 100mV / 10mV / 1mV per A (AC coupled) |
Accuracy | (at 25°C) ± 1% of reading ± 0.1A (30A range) ± 1% of reading ± 1A (300A / 3000A range) |
General Characteristics
Probe and Cable Material | Alcryn 2070 NC LATENE 7H2W V0 |
Probe Cable Length | 610mm (24”) / 915mm (36”) / 1220mm (48”) |
Probe Cable Diameter | 9.9mm (nominal) |
Cable Length | 2m (Probe to Integrator box) |
Output | 0.5m long lead terminated with a safety male BNC |